A pioneer in the field of clinical chemistry photometers
HumaLyzer 4000
The HumaLyzer 4000 stands as a pioneering force in the field of clinical chemistry photometers, built upon a foundation of reliable German engineering and manufacturing. It is specifically designed for exceptional performance in human diagnostics, featuring more than 50 pre-validated settings to ensure optimal and accurate results with HUMAN reagents right from the start. This commitment to precision is further enhanced by its advanced reference channel optics, which guarantees high measurement accuracy and consistency, making the HumaLyzer 4000 a trusted and efficient solution for any modern laboratory.
- Reliable German engineering and manufacturing
- More than 50 validated settings for HUMAN reagents
- High precision with reference channel optics
HumaLyzer 4000
Setting new standards for semi-automated photometers
The HumaLyzer 4000’s development was a collaborative effort with our affiliated company, LABiTec®, ensuring compliance with strict European In-Vitro Diagnostic (IVD) standards from the very beginning. This commitment to quality and regulatory excellence is further underscored by its German manufacturing origin. The device’s proven reliability and performance have led to its successful deployment and trust in over 70 countries worldwide, making it a truly global solution for clinical chemistry analysis.
Smart hardware solutions
- Large touch screen
- Low energy consumption
- Lamp save mode – warm-up within seconds
- Built-in incubator block 10 round and 2 square positions
Excellent data handling
- Data management via onboard results, database, LIS or csv-export
- External mouse and keyboard for quick input of patient data
- Handheld barcode scanner for samples
User friendly
- Multilanguage interface
- Fast Run or Worklist customize your workflow
- Automatic maintenance reminders (e.g. cleaning)
- Simple update of software and settings via USB stick
Robust and cost efficient
- Service by user, no technician necessary
- Lamp life time of > 5000 h
- Basic wear and tear parts can be replaced without special tools by laboratory staff
- No cleaning of interference filters required (sealed photometer module)
Validated reagent settings preinstalled
High quality multipurpose reagents
We produce our reagents in accordance with the latest quality standards.
More than 50 validated settings of HUMAN reagents are preinstalled
| A-G | REF |
|---|---|
| ALBUMIN liquicolor | 10560, 156004 |
| ALKALINE PHOSPHATASE liquicolor* | 12117 |
| alpha-AMYLASE liquicolor | 12218, 12018 12028 |
| anti-Streptolysin-O (ASO) | 112519 |
| APOLIPOPROTEIN A1 (APO A1) | 11101 |
| APOLIPOPROTEIN B (APO B) | 11102 |
| auto-BILIRUBIN-D liquicolor | 10741 |
| auto-BILIRUBIN-T liquicolor | 10742 |
| auto-CREATININE liquicolor | 10052 |
| CALCIUM liquicolor | 10011 |
| CHLORIDE liquicolor | 10115 |
| CHOLESTEROL liquicolor | 10017, 10019 10028 |
| CHOLINESTERASE liquicolor | 12007 |
| CK NAC activated liquidUV* | 12015 |
| CK-MB liquidUV* | 12118 |
| CREATININE (enzym) liquicolor | 10053 |
| CRP | 11241 |
| CYSTATIN-C liquidirect | 11150 |
| gamma-GT liquicolor* | 12213, 12013, 12023, 12033 |
| GLUCOSE liquicolor | 10121, 10260 |
| GLUCOSE liquidV/mono | 10786 |
| GOT (ASAT) IFCC mod. liquidV* | 12211, 12011 12021, 12031 |
| GPT (ALAT) IFCC mod. liquidV* | 12212, 12012, 12022, 12032 |
| H-U | REF |
|---|---|
| HbA1c liquidirect | 10770 |
| HDL CHOLESTEROL liquicolor | 10084,10284 |
| HEMOGLOBIN liquicolor | 10751 |
| IMMUNOGLOBULINS direct IgA | 11501 |
| IMMUNOGLOBULINS direct IgG | 11502 |
| IMMUNOGLOBULINS direct IgM | 11503 |
| IRON liquicolor | 10229,10230 |
| IRON TPIZ liquicolor | 12290,12291 |
| LDL CHOLESTEROL liquicolor | 10094,10294 |
| LIPASE liquicolor | 12006,12026 |
| MAGNESIUM liquicolor | 10010 |
| MICROALBUMIN | 11120 |
| PANCREAS-AMYLASE liquicolor | 12009,12029 |
| PHOSPHORUS liquirapid | 10027 |
| RHEUMATOID FACTORS (RF Latex) | 11261PA |
| RHEUMATOID FACTORS (RF) | 11261P |
| SODIUM liquicolor | 10113 |
| TOTAL PROTEIN liquicolor | 157004,10570 |
| TRANSFERRIN | 11115 |
| TRIGLYCERIDES liquicolor mono | 10720P,10724,10725 |
| UREA liquicolor* | 10505,10506,10507 |
| UREA liquiUV | 10521 |
| URIC ACID liquicolor | 10690,10691 |
| URIC ACID liquicolorplus | 10694 |
Innovative, convenient and reliable
Tutorial videos for staff training and an easy start
Included with the HumaLyzer 4000 are 5 video training tutorials.
Supplementing the user manual, these provide a quick visual
overview of the functionality and operation of your new instrument.
Register here to watch the first tutorial for free:
The reference channel, usually only found in automatic analyzers,
reduces signal noise and increases the precision of the measurement.
It also allows the instrument to wake up from lamp save mode in
only a few seconds. The light of the lamp is divided into a
measuring channel and a reference channel.
The reference channel can compensate for
drifts and fluctuations of the lamp or filters
Quality and precision with reference channel technology
Many patients in rural areas travel long distances to health centers to receive
a diagnosis and therapy. Therefore, it is important to ensure that the results
are accurate and available in a timely manner to ensure appropriate therapy.
The HumaLyzer 4000 can even run for almost up a full working day (4-8 hours) off-grid with the optional HUMAN battery pack. For greater flexibility, the battery pack can also be recharged using the optional solar panel.
Independence from mains - reliable results under challenging conditions
HUMAN clinical chemistry reagents are manufactured to the highest quality standards at the HUMAN production facility in Germany. HUMAN offers ready-to-use, liquid stable reagents in different convenient kit sizes. The validated settings are pre-programmed on the HumaLyzer 4000 and the whole clinical chemistry intrument line.
Multipurpose reagents with validated settings - Made in Germany
Analyzer overview
| Analyzer type | Semi-automatic photometer |
| Reagent system | Open |
| Reaction system | Flow cell or square cuvette |
| Incubator | Built-in: 10 round, 2 square positions; optional external incubator |
| HumaCube (220V) REF 17050 | |
| HumaCube (110V) REF 17070 | |
| Printer | Built-in, thermal printer |
Optical overview
| Overview | Reference channel optics with 8 different interference filters and 5W halogen reflector lamp |
| Photometer performance | Linearity 0.01 to 2.5 OD, Resolution 0.001 mAbs |
Consumable
| Flow Cell Cleaner 100 ml | REF 18222 |
Ordering information
| Humalyzer 4000 | REF 18250 |
| Battery Pack | |
| Portable Battery System 73Wh | REF 18250/74 |
| Solar Panel | |
| for recharging of 73 Wh battery | REF 18250/73 |
| External Barcode Scanner | |
| Includes 1D barcode scanner and adapter cable | REF 18250/76 |
| Humalyzer Calibration Tool Set | |
| Includes grey glass filter and reference values, aluminum block and USB stick for backup | REF 60600 |
Analyzer operation
| User interface | Color touch screen |
| Measuring modes | Photometry (colorimetry, UV-tests, turbidimetry) |
| Liquid handling | Peristaltic pump |
Memory
| Result storage | 10,000 results incl. reaction curve, method and calibration in searchable database + more on internal SD card (8 GB) |
| Method storage | 144 method positions, including over 50 validated methods for HUMAN reagents plus user programmable methods |
| QC module | Up to 4 levels of controls, monitored via QC periods and Levey Jennings charts |